What do we consider as anti-Legionella design in domestic hot water storage tanks?

English
Respuesta: 
Bacterial proliferation such as “Legionella” inside the domestic hot water storage cylinders, should be avoided from the design of the storage tank itself, with heating systems that avoid “cold areas” (<40 ºC), or with storage temperatures clearly lower than that of the tank. As an example of “anti-Legionella” design, we propose our "double wall" models, with total temperature homogeneity inside the cylinder and made of stainless steel as the hygienic material for excellence. All our models with heating coils also take into account this phenomenon, and are designed with geometries adapted to heating from the bottom of the storage tank, thus avoiding cold areas or areas with the possibility of bacteria proliferation.